R290 Mono-NanoTherm
4~6kW
Label:
Category:


Integrated system

Specifications
| Outdoor unit | AMH-4R2 | AMH-6R2 | |||
| Heating | Heating(1) A7W35 |
Capacity | kW | 4.60 | 6.20 |
| Power input | kW | 0.88 | 1.24 | ||
| COP | W/W | 5.25 | 5.00 | ||
| Heating(2) A7W45 |
Capacity | kW | 4.60 | 6.30 | |
| Power input | kW | 1.12 | 1.64 | ||
| COP | W/W | 4.10 | 3.85 | ||
| Heating(3) A7W55 |
Capacity | kW | 4.60 | 6.30 | |
| Power input | kW | 1.39 | 1.97 | ||
| COP | W/W | 3.30 | 3.20 | ||
| Heating(4) A2W35 |
Capacity | kW | 4.50 | 5.70 | |
| Power input | kW | 1.11 | 1.50 | ||
| COP | W/W | 4.05 | 3.80 | ||
| Heating(5) A-7W35 |
Capacity | kW | 4.70 | 5.80 | |
| Power input | kW | 1.52 | 2.04 | ||
| COP | W/W | 3.10 | 2.85 | ||
| Cooling | Cooling(6) A35W18 |
Capacity | kW | 4.60 | 6.40 |
| Power input | kW | 0.84 | 1.27 | ||
| EER | W/W | 5.50 | 5.05 | ||
| Cooling(7) A35W7 |
Capacity | kW | 4.70 | 6.70 | |
| Power input | kW | 1.31 | 2.09 | ||
| EER | W/W | 3.60 | 3.20 | ||
| DHW | Tappling profile according EN16147 | / | / | ||
| Water heating energy efficiency class(8) | Warm climate | class | / | / | |
| COP | / | / | |||
| Average climate | class | / | / | ||
| COP | / | / | |||
| Seasonal space heating energy efficiency class (9) | Water outlet @35℃ | class | A+++ | ||
| Water outlet @55℃ | class | A+++ | |||
| Outdoor unit | Power supply | V/Ph/Hz | 220-240/1/50 | ||
| Net dimension(W*H*D) | mm | 840*880*500 | |||
| Packing dimension(W*H*D) | mm | 940*1055*570 | |||
| Net weight | kg | 87 | |||
| Gross weight | kg | 101 | |||
| Refrigerant | Type/GWP | / | R290/3 | ||
| Charge | kg | 0.68 | |||
| Sound power level(10) | dB(A) | 54 | 56 | ||
| Sound pressure level (1 meter distance) |
dB(A) | 42 | 44 | ||
| Operating ambient temperature | Cooling | ℃ | -5~48 | ||
| Heating | ℃ | -26~35 | |||
| DHW | ℃ | -26~43 | |||
1.Evaporator air in 7℃,85% R.H.,Condenser water in/out 30/35℃.
2.Evaporator air in 7℃,85% R.H.,Condenser water in/out 40/45℃.
3.Evaporator air in 7℃,85% R.H.,Condenser water in/out 47/55℃.
4.Evaporator air in 2℃,82% R.H.,Condenser water in/out 30/35℃.
5.Evaporator air in -7℃, --R.H.,Condenser water in/out 30/35℃.
6.Condenser air in 35℃.Evaporator water in/out 23/18℃.
7.Condenser air in 35℃.Evaporator water in/out 12/7℃.
8.According to EN16147/2017;EU No:811/2013
9.According to EN14511/2018; EN14825/2018; EU No:811/2013
10. Sound power in heating mode, measured according to the EN 12102 under conditions of the EN 14825
The final parameters of the product are subject to the state when the product is put into production and released.

Quote Now