R290 Mono Heat Pump

4~32kW

• R290 natural refrigerant with Low GWP-3 • Maximum water temperature up to 75℃ • Seasonal energy efficiency class up to A+++ • Full DC inverter system guarantees superior efficiency • Fully sealed electric control box with explosion-proof feature • Full-color touch screen wired controller • Remote update and monitor

Label:

Category:


Application Scenario

The AS thermal-i Heat Pump, tailored for Europe, offers a complete solution for heating, cooling, and domestic hot water.

 

 

The AS thermal-i series of heat pump products can also be integrated into the "Household Energy Management System"(EMS) and connected with solar photovoltaic products, forming a more efficient, smart and environmentally friendly comprehensive solution for the digital & intelligent operation and maintenance of all household appliances (Customized).

 

 

High Reliability

 

 

Internet of Things(IoT)

 

 

Specifications

 

Outdoor unit AMH-4R2 AMH-6R2 AMH-8R2 AMH-10R2 AMH-12R2
Indoor unit / AMHTB-190R2T60 AMHTB-240R2T60
Heating Heating(1)
A7W35
Capacity kW 4.60  6.20  8.3 10 12.3
Power input kW 0.88 1.24 1.63 2.11 2.47
COP W/W 5.25 5.00  5.09 4.73 4.98
Heating(2)
A7W45
Capacity kW 4.60  6.30  8.2 10 12.2
Power input kW 1.12 1.64 2.07 2.69 3.14
COP W/W 4.10  3.85 3.96 3.72 3.88
Heating(3)
A7W55
Capacity kW 4.60  6.30  7.8 9.5 12.4
Power input kW 1.39 1.97 2.36 3.01 3.89
COP W/W 3.30  3.20  3.31  3.16 3.19
Heating(4)
A2W35
Capacity kW 4.50  5.70  7.1 8.3 11.0
Power input kW 1.11 1.50 1.86 2.26 2.97
COP W/W 4.05  3.80  3.81  3.68  3.70
Heating(5)
A-7W35
Capacity kW 4.70  5.80  7.2 8.2 10.9
Power input kW 1.52 2.04 2.42 2.97 3.76
COP W/W 3.10  2.85  2.97  2.76  2.90
Cooling Cooling(6)
A35W18
Capacity kW 4.60  6.40  8.4 10 12.4
Power input kW 0.84 1.27 1.62 2.1 2.66
EER W/W 5.50  5.05 5.17  4.75 4.67
Cooling(7)
A35W7
Capacity kW 4.70  6.70  7.5 8.6 11.6
Power input kW 1.31 2.09 2.17 2.70 3.61
EER W/W 3.60  3.20  3.45  3.18  3.21
DHW Tappling profile according EN16147 / / L XL
Water heating energy efficiency class(8) Warm climate class / / A+ A+ A+
COP / / 3.55  3.55  3.64
Average climate class / / A+ A+ A+
COP / / 2.93  2.93  3.18
Seasonal space heating energy efficiency class (9) Water outlet @35 class A+++
Water outlet @55 class A+++ A++
Outdoor unit Power supply V/Ph/Hz 220-240/1/50
Net dimension(W*H*D) mm 840*880*500 1155*950*500
Packing dimension(W*H*D) mm 940*1055*570 1240*1125*570
Net weight kg 87 119 139
Gross weight kg 101 134 154
Refrigerant Type/GWP / R290/3
Charge kg 0.68 1.07 1.35
Sound power level(10) dB(A) 54 56 56 59 63
Sound pressure level
 (1 meter distance)
dB(A) 42 44 44  47  51 
Operating ambient temperature Cooling -5~48
Heating -26~35
DHW -26~43
Indoor unit Power supply V/Ph/Hz / 220-240/1/50
Net dimension(D*W*H) mm 775*600*1750 775*600*2005
Packing dimension(D*W*H) mm 875*730*1895 875*730*2150
Net weight kg 166  184 
Gross weight kg 181  199 
Expansion vessel Volume L
Water Piping connection Water circuit (inlet/outlet) G1"
DHW tank water circuit (inlet/ Outlet/Recirculation) G3/4"
Backup E-heater Customizable 3kW: 220-240V/1Ph/50Hz
6kW or 9kW: 380-415V/3Ph/50Hz
DHW Tank Type Stainless steel
Material Duplex stainless stell 2205
Maximum water pressure limit bar 8
Water Volume L 190 240
Buffer tank Volume(10) L 60 60
Outlet water setting temperature(10) Cooling 5~25
Heating 20~75
DHW 30~70
Sound power level(10) dB(A) 39 39 41

 

Outdoor unit AMH-14R2 AMH-16R2 AMH-12TR2 AMH-14TR2 AMH-16TR2
Indoor unit AMHTB-240R2T60 AMHTB-240R2T60
Heating Heating(1)
A7W35
Capacity kW 14.1 15.3 12.2 14.2 15.3
Power input kW 3.03 3.37 2.51 3.11 3.44
COP W/W 4.65 4.54 4.86 4.57 4.45
Heating(2)
A7W45
Capacity kW 14.3 15.4 12.1 14.4 15.5
Power input kW 3.90 4.28 3.12 3.92 4.34
COP W/W 3.67 3.60 3.88 3.67 3.57
Heating(3)
A7W55
Capacity kW 14.3 15.5 12.4 14.4 15.6
Power input kW 4.63 5.13 3.84 4.60 5.11
COP W/W 3.09 3.02 3.23 3.13 3.05
Heating(4)
A2W35
Capacity kW 12.3 13.2 11.0 12.3 13.3
Power input kW 3.49 4.01 3.00 3.48 4.01
COP W/W 3.52 3.29 3.67 3.53 3.32
Heating(5)
A-7W35
Capacity kW 12.1 13.2 10.7 11.8 13.0
Power input kW 4.29 4.84 3.78 4.31 4.92
COP W/W 2.82 2.73 2.83 2.74 2.64
Cooling Cooling(6)
A35W18
Capacity kW 14.2 16.3 12.4 14.2 16.2
Power input kW 3.21 3.89 2.64 3.18 3.88
EER W/W 4.42 4.19 4.69 4.47 4.18
Cooling(7)
A35W7
Capacity kW 13.3 14.5 11.40 13.2 14.6
Power input kW 4.45 5.05 3.61 4.43 5.05
EER W/W 2.99 2.87 3.16 2.98 2.89
DHW Tappling profile according EN16147  
Water heating energy efficiency class(8) Warm climate class A+ A+ A+ A+ A+
COP 3.64 3.64 3.43 3.43 3.43
Average climate class A+ A+ A+ A+ A+
COP 3.18 3.18 3.04 3.04 3.04
Seasonal space heating energy efficiency class (9) Water outlet @35℃ class A+++
Water outlet @55℃ class A++
Outdoor unit Power supply V/Ph/Hz 220-240/1/50 380-415/3/50
Net dimension(W*H*D) mm 1155*950*500
Packing dimension(W*H*D) mm 1240*1125*570
Net weight kg 139 148
Gross weight kg 154 163
Refrigerant Type/GWP / R290/3
Charge kg 1.35 1.35
Sound power level(10) dB(A) 64 65 63 64 65
Sound pressure level
 (1 meter distance)
dB(A) 52  53  51  52  53 
Operating ambient temperature Cooling -5~48
Heating -26~35
DHW -26~43
Indoor unit Power supply V/Ph/Hz 220-240/1/50 380-415/3/50
Net dimension(W*H*D) mm 775*600*2005 775*600*2005
Packing dimension(W*H*D) mm 875*730*2150 875*730*2150
Net weight kg 184  184  184  184  184 
Gross weight kg 199  199  199  199  199 
Expansion vessel Volume L
Water Piping connection Water circuit (inlet/outlet) G1"
DHW tank water circuit (inlet/ Outlet/Recirculation) G3/4"
Backup E-heater Customizable 3kW: 220-240V/1Ph/50Hz
6kW or 9kW: 380-415V/3Ph/50Hz
DHW Tank Type Stainless steel
Material Duplex stainless stell 2205
Maximum water pressure limit bar 8
Water Volume L 240
Buffer tank Volume(10) L 60
Outlet water setting temperature(10) Cooling 5~25
Heating 20~75
DHW 30~70
Sound power level(10) dB(A) 43 43 41 43 43

 

Outdoor unit (AMH-) 18TR2 20TR2 24TR2 28TR2 32TR2
Heating
A7W35
Capacity kW 17.69  19.29  24.16  28.12  30.91 
Power input kW 3.74  4.20  5.15  6.39  7.15 
COP W/W 4.73  4.59  4.69  4.40  4.32 
Heating
A7W45
Capacity kW 17.63  19.58  23.96  28.37  31.16 
Power input kW 4.73  5.37  6.36  7.97  8.99 
COP W/W 3.73  3.65  3.77  3.56  3.47 
Heating
A7W55
Capacity kW 17.95  19.43  24.43  28.51  31.28 
Power input kW 5.77  6.36  7.75  9.25  10.43 
COP W/W 3.11  3.06  3.15  3.08  3.00 
Heating
A2W35
Capacity kW 15.54  16.57  21.90  24.48  26.33 
Power input kW 4.29  4.72  6.08  7.07  8.09 
COP W/W 3.62  3.51  3.60  3.46  3.25 
Heating
A-7W35
Capacity kW 15.04  15.93  21.40  23.48  25.74 
Power input kW 5.17  5.58  7.71  8.74  10.00 
COP W/W 2.91  2.85  2.77  2.69  2.57 
Cooling
A35W18
Capacity kW 18.20  20.10  24.55  28.40  32.08 
Power input kW 4.07  4.73  5.26  6.48  7.87 
EER W/W 4.47  4.25  4.67  4.38  4.08 
Cooling
A35W7
Capacity kW 16.63  17.35  22.80  26.27  29.05 
Power input kW 5.45  5.74  7.32  8.95  10.26 
EER W/W 3.05  3.02  3.11  2.94  2.83 
Net dimension(W*H*D) mm 1155*1205*500 1155*1830*500
Packing dimension(W*H*D) mm 1240*1380*570 1240*1995*570
Net weight kg 173 276 
Gross weight kg 188 292 
Fan motor Quantity / 1
Power/1 motor W 200 200 
Compressor Quantity / 1
Type / DC inverter
Regrigerant Type/GWP / R290/3
Charge kg 1.95 2.75 
Seasonal spacing heating energy efficiency Water outlet @35 class A+++
Water outlet @55 class A++
Sound power level dB(A) 66  67  66  67  68 
Sound pressure level (1 meter distance) dB(A) 54  55  54  55  56 
Operating ambient temperature Cooling -5~48
Heating -28~35
DHW -28~43
Outlet water setting temperature Cooling 5~25
Heating 20~75
Water tank setting temperature DHW 30~70

 

6.Condenser air in 35℃.Evaporator water in/out 23/18℃.                                
7.Condenser air in 35℃.Evaporator water in/out 12/7℃.                                
8.According to EN16147/2017;EU No:811/2013                                
9.According to EN14511/2018; EN14825/2018; EU No:811/2013                                
10. Sound power in heating mode, measured according to the EN 12102 under conditions of the EN 14825                                
The final parameters of the product are subject to the state when the product is put into production and released.                                
 

File Download


图片名称

test file

Update time:

2025-07-07

Quote Now


We will contact you within one working day. Please pay attention to your email. 

视频标题

Get A Free Quote

Leave your contact information to get a free product quote


Enter product details such as dimensions, materials, etc. and other specific requirements to get an accurate quote.
SUBMIT